General Description
arrow Sloped Insulation
  Built Up Roofing
  Single Ply Roofing
  Standing Seam
  Fire Rated Assemblies
  Modified Bitumen
  Cathedral Ceilings
 
  Home > Installation Applications > Roofing Applications  
 

Sloped Insulation

  tapered_roof

PlastiSpan sloped roof insulation provides the required positive slope to drain while retaining the structural and economic advantages provided by a flat roof deck. PlastiSpan sloped insulation board can be used for new and maintenance roofing projects of all sizes and is suitable for use with all types of roofing systems. Because PlastiSpan sloped insulation board is an expanded polystyrene (EPS) insulation, design thermal resistance values provided are not subject to thermal drift.

Calculation of Thermal Resistance for Sloped Insulation
The average thermal resistance for a sloped insulation layout is calculated as the value for the average insulation thickness over the entire roof. The average thermal resistance value provides a reasonable estimate of the thermal performance of the insulation component in the roof assembly.

Slope to Drain
PlastiSpan sloped roof insulation is available with slopes of 1/2%, 1%, 1-1/2%, 2%, 3%, 4%, and 8% per meter (per foot). Normally, ridges and valleys necessary to provide correct drainage are supplied at 45º increments to the horizontal, however, custom angles can also be provided.

Insulation boards are laid in a predetermined pattern using 1200 mm by 1200 mm (4 ft x 4 ft) boards to provide slope to interior drains or scuppers at the edges of the building. Even the prefabricated corners for the change of slope are provided using 1200 mm by 1200 mm (4 ft x 4 ft) boards in order to maintain uniformity in the layout.

Computer Designed Sloped Insulation Layouts
As a service to its customers, Plasti-Fab will provide sloped insulation layouts designed on a customized computer program. The Plasti-Fab computerized design process allows alternate insulation slope and drain layouts to be quickly evaluated, thus ensuring the most efficient and cost effective sloped insulation layout is provided.

software

pdf To view the design manual document on Sloped Roofing, Click Here

Please note that you need to be logged on to view this brochure. Go to login or registration page now.